WHEN MUST WE ISOLATE IEEE Std. 487-1992 states that you do not have to use isolation on wire-line communications if the GPR is less than 1000V-Peak Asymmetrical, because not doing so will not result in a fire. However, a GPR under 1000V will still damage cable and equipment, and possibly harm personnel. Also, this standard does not directly address the need for isolation of wire-line communications in locations other than in power-type high-voltage environments, because of its mandate to only address those environments. Thus, there is presently no standard that addresses the dangers of GPR resulting from lightning strike energy in non-power environments. To protect personnel and equipment from the possible effects of a GPR, you should consider using isolation equipment on all wire-line communication services where the calculated GPR will be over 300V-Peak. If you have any highly reliable Class-A services that you want to continue to function at all times, even during a GPR, then you must use isolation no matter what the calculated GPR. Any tower, antenna, or other object that is higher than surrounding objects, is at risk of being struck by lightning. Thus, these locations are susceptible to the resulting GPR from lightning strike energy passing down through the impedance of that grounding system, and isolation must be considered if equipment damage, personnel safety or communications reliability is a concern. As you may be aware, standard grounding devices, i.e., gas tubes, MOVs, SADs, etc., that shunt energy on wire-line services to ground, will not protect those services from a GPR. In fact, these very fast acting devices will actually fire backwards placing the current from a GPR back on the line. Obviously, in cases related to power line faults, the better the cell site grounding system, the lower the GPR. This is basic "Ohms Law" --Voltage is equal to current multiplied by (x) resistance, in cases related to power line faults. However, in the case of lightning strike energy, the equation is: V=Ldi/dt. Very conservatively, an average 30kA lightning strike will produce a 7.5kV GPR. See On The Road with Ernie #7' at this web site. A 100kA lightning strike will produce a 25kV GPR. Although rare, super strokes of 400kA are known to exist. However, dont be fooled in believing that good grounding systems can be had easily. No matter how hard you attempt to provide a good grounding system for the cell site equipment that matches the grounding system of the object that it is using for an antenna, you will not be successful. Consider this; for every foot of 4/0 ground conductor, there is approximately 1.5kV of voltage drop at lightning frequencies. Thus, as an example; a cell site grounding system could be grounded to a water tower grounding system (very good ground) located just ten feet away with a 4/0 ground conductor, and still have a 15kV difference in potential at lightning strike frequencies. Maintaining reliable, safe and maintenance free wire-line service, year after year,
requires the use of isolation equipment in GPR locations and very good grounding systems.
Don't be lulled into a false sense of safety just because your grounding system is
tied into another very good grounding system. Remember, at lightning frequencies,
just a few feet of heavy ground conductor (4/0) can represent a significant difference in
potential between two grounding systems. It is critical that cell sites such as the one shown below have well engineered isolation protection and grounding as was assured by expert quality control by Ernest Duckworth, P.E. The site pictured
above has
state-of-the-art protection and grounding with quality assured. New! Lightning Protection Checklist for Risk Management New ! Lightning Protection Guide for protecting equipment and personnel New ! Lightning Storm Dot Com view the current lightning map of the United States New ! Lightning and GPR Related Links New ! Lightning Related Articles New ! Lightning Related Reference Books New ! Wire-Line Communications Isolation or Fiber Optic Facility Extensions ? Solving High Voltage Problems In Wireless/Utility Collocations Eliminating Lightning Damage at PCS Cell Sites Isolation of Wire-line Communications in an Unregulated Power Market PCS Locations in High-Voltage Corridors Be alert to the Danger of GPR On the Road With Ernie Great Balls of Fire! Destructive Surges Wireline Isolation Theory and Application When to Protect Cell Sites from GPR Links to US Energy Utilities Communications Related Links Return to GPR Expert Home
|